Double Ended Load Cell
Double Ended Load Cell

Double Ended Load Cell

Price 9500 INR/ Unit

MOQ : 1 Unit

Double Ended Load Cell Specification

  • Resistance
  • Input: 700 +/- 7 Ohms; Output: 703 +/- 4 Ohms
  • Type
  • Double Ended Shear Beam
  • Accuracy
  • OIML C3
  • Operating Voltage
  • 5 to 12V DC
  • Output Voltage
  • 2 mV/V
  • Compensated Temperature
  • -10 to +40 Deg C
  • Operating Temperature
  • -35 to +65 Deg C
  • Application
  • Pallet Truck Scales
  • Protection Class
  • IP69K
  • Mounting Type
  • Double Ended
  • Combined Error
  • +/- 0.035% FS
  • Temp Effect Output
  • +/-0.011% FS/DegC
  • Zero Balance
  • +/- 1% FS
  • Model
  • B9C
  • Insulation Resistance
  • >= 5000 M Ohm
  • Creep Error
  • +/- 0.016% FS
  • Ultimate Overload
  • 300% FS
  • Max Safe Overload
  • 150% FS
  • Material
  • Stainless Steel
  • Max Excitation Voltage
  • 18V DC
  • Ingress Protection
  • IP67
  • Features
  • High Accuracy Precision
  • Capacity
  • 112.5 Kg
  • Output Sensitivity(FS)
  • 3.0 +/- 0.003 mV/V
  • Temperature Effect Zero
  • +/-0.016% FS/DegC
 

Double Ended Load Cell Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Double Ended Load Cell



Capitalise on precision and durability with the dominant Double Ended Load Cell, Model: B9C. Manufactured from excellent stainless steel, this ace device offers high accuracy for pallet truck scales with a superb capacity of 112.5 Kg. Benefit from its outstanding output sensitivity (3.0 0.003 mV/V) and extremely low error rates. Enjoy maximum safety with overload protection up to 300% FS. Purchase directly from India's leading manufacturer and supplier at the lowest price, ensuring both reliability and value in commercial applications.

Unlock Commercial Excellence with Double Ended Load Cell

Engineered for demanding commercial environments, the Double Ended Load Cell excels in heavy-duty applications like pallet truck scales. Its double-ended shear beam design ensures stable mounting and precise measurement on various industrial surfaces. Featuring high accuracy (OIML C3), waterproof protection (IP69K, IP67), and robust overload capabilities, this load cell is the go-to choice for factories, warehouses, and logistic hubs that require dependable and consistent performance.


Sample Access, Certifications, and Quick Rate Quotations

Sample units of the Double Ended Load Cell are available for quality evaluation, supported by a clear sample policy. All products come certified to ensure compliance and performance. Transport services provide secure and prompt delivery. Upon inquiry, customers receive an upfront rate and detailed outlay of costs. This approach guarantees you can assess the product's fit for your needs and budget before a full purchase, streamlining your procurement process.


FAQ's of Double Ended Load Cell:


Q: How does the Double Ended Load Cell ensure high accuracy in commercial applications?

A: The Double Ended Load Cell offers OIML C3-grade accuracy with minimal combined and creep error, ensuring precise measurements in demanding commercial environments, such as pallet truck scales.

Q: What makes the Model B9C suitable for pallet truck scale usage?

A: Its robust stainless steel build, double-ended shear beam design, and high output sensitivity make the B9C ideal for the rugged, repetitive loading scenarios found in pallet truck scales.

Q: When can I request a sample unit and what is the process?

A: Sample units are available on request. Following your inquiry, a representative will provide details on sample policy, applicable rates, and arrange transport services to deliver a test unit promptly.

Q: Where can the Double Ended Load Cell be mounted?

A: It is designed for double-ended mounting on industrial surfaces, providing stability and accuracy when integrated into pallet trucks or similar weighing platforms.

Q: What are the benefits of this load cell's protection ratings?

A: With IP69K and IP67 ingress protection, the load cell performs reliably in wet, dusty, or corrosive environments, minimizing downtime and maintenance costs.

Q: How does certification enhance the reliability of this product?

A: Certified to OIML C3 and additional industry standards, the Double Ended Load Cell assures quality, repeatability, and peace of mind in all commercial weighing applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Load Cell Category

Platform Load Cell

Platform Load Cell

Price 1500 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Single Point

Accuracy : OIML C3

Output : Other, Analog, mV/V

Operating Voltage : 9 to 12V DC

S Type Load Cell

S Type Load Cell

Price 3000 INR / Unit

Minimum Order Quantity : 1 Unit

Type : S Type Load Cell

Accuracy : 0.05 %

Output : Other, Analog

Operating Voltage : 5 to 15V DC

Single beam load cell

Single beam load cell

Price 2800 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Single Ended Shear Beam

Accuracy : OIML C2

Output : Other, 2 mV/V

Operating Voltage : 10 to 12V DC

Load Cell S Type

Load Cell S Type

Price 3500 INR / Unit

Minimum Order Quantity : 1 Unit

Type : S Type

Accuracy : 0.1 %

Output : Other, Analog Output

Operating Voltage : 515V DC



Back to top